You must be able to:
Measure, mark out, mix, apply and fit make good including any defects
Carry out external pre-installation checks, assessing, recording and reporting issues to include:
suitable access
background condition and suitability
identification of the product used against specification
fixing integrity
vegetation
rainwater goods and system penetrations
position of damp proof course
vents and ventilation
services (gas, electric, water, media cables and signal receiving equipment)
Use and maintain all work tools and equipment
Check or apply protection to openings, fixtures and surrounding areas against the risk of damage
Apply corner and surface beads, trims day breaks/joints and expansion joints
Apply base coats, reinforcing mesh and stress patches in accordance with the design and checking at each stage for:
cracking
dampness
Apply sealant tapes and strips in line with the system designer specification
Prepare and apply external wall insulation (EWI) surface finishes to system designer specification, method statement and the required standard for:
dash finishes
synthetic or non-synthetic renders
Fit weather seals and mastics in line with specification
Reinstatement of external furniture such as rainwater goods and systems penetrations
Carry out post installation checks and handover
Carry out post installation repairs and handover
You must know and understand:
How the methods of work to meet the specification and any unintended consequences are identified, reported and actioned
How problems are identified, reported and actioned as per specification following safe, healthy and environmental work practices
How to comply with procedures and skills relating to the areas of work as per specification
Check the design and specification against the materials to be fitted
How to identify record and report issues or defects with the materials, components and finishes
Why it is important to carry out pre- finishes checks
How to carry out pre-installation checks, assessing, recording and reporting issues that may inhibit commencement to include but not limited to:
suitable access
background condition and suitability
identification of product used against specification
fixing integrity
vegetation
damp proof course
trim projections, cills and overhang protections such as vents, glazing, doors, floors and roofs
vents, ducts, flues, rainwater goods and system penetrations
services (gas, electric, water, media cables and signal receiving equipment)
protections, such as vents, glazing, doors, floors and roofs
How and why, it is important to check, record and report issues with construction ventilation, flues, chimneys and combustion air ventilators pre and post installation
Why it is important to identify and report potential thermal bridging
How to recognise, record and report the key issues that may inhibit commencement of the work including but not limited to:
condition of the background insulation
identification of any areas of potential water penetration
visibility and completeness of damp proof course
condition of window and door seals and reveal depths
cill overhangs
condition of roof interface and overhangs
rainwater goods and systems penetrations
protection and existence of vents and ventilation to include sub floor ventilation
services (gas, electric, water, media cables and signal receiving equipment)
flues, gas pipes, and chimneys and combustible air ventilators
identification of protected wildlife (nesting birds, bees, bats)
vegetation
How to identify when specialist skills and knowledge are required and report accordingly including but not limited to:
suitable access
vents, ducts, flues, rainwater goods and system
services (gas, electric, water, media cables and signal receiving equipment)
asbestos
surface defects
heritage and architectural defects
ecology
fire safety
penetrations
How and why to identify, record, report unintended consequences not addressed in the design
Why it is important to avoid unintended consequences not addressed in the design
How to protect the adjacent surfaces and work areas
Why it is important to explain installation procedure to building occupants to include but not limited to the following:
scope and work programme
safety requirements during the installation process
protection of property and personal items
specific benefits and implications to include homeowner information
agreed standards of making good
How not to compromise the function of but not limited to:
windows & doors
damp proof course
How to work with, around and in close proximity to plant and machinery
How to identify and follow the installation quality requirements as per specification
How to ensure materials are as per specification and report any inaccuracies and defects
How to fix corner surface beads and trims as per specification
How and when to apply base and primer coats, reinforcing mesh and stress patches
How to fit weather seals at interfaces, window and door reveals and at system penetrations in accordance with the specification, design drawings and method statements
How to apply dash finishes, synthetic and non-synthetic renders, paint finishes, brick slips and brick effect render to external wall insulation system including door and window reveals
How to reinstate fixtures and fittings and seals in accordance with the specification, design drawings and method statements
How to use all work tools and installation equipment
How to work at height using access equipment and harness systems
How and why maintenance of all work tools and installation equipment is carried out
Why and how to complete post installation checks, compliance with specifications, including penetrations, fixtures and fittings and report any issues
How to carry out any repairs after installation
Why it is important to immediately record and report unforeseen events including but not limited to materials, equipment malfunctions, situations and faults not identified in the original design
Why it is important to provide post installation advice and guidance to building occupants and client including homeowner packs
How to handover and sign off to the site manager, client or homeowner satisfaction