• language Language
  • Trade specific competencies
  • Overview
  • Sector overview
  • Routes to competence
  • Functional map (Install)
  • Functional map (Maintain)
  • Functional map (Repair)
  • Core construction competencies
    • Conform to general health, safety and welfare (CC001)
    • Conform to productive working practices (CC002)
    • Move, handle and store resources (CC003)
  • Core trade competencies
    • Interpret Information
    • Safe work practices
    • Selection of resources
    • Minimise the risk of damage
    • Approach to work
  • Trade specific competencies
    • Install manual fire-resisting door, shutter or curtain systems (FRDSC001)
    • Install powered fire-resisting door, shutter or curtain systems (FRDSC002)
    • Maintain manual fire-resisting door, shutter or curtain systems (FRDSC003)
    • Maintain powered fire-resisting door, shutter or curtain systems (FRDSC004)
    • Dismantle and Repair manual fire-resisting door, shutter or curtain systems (FRDSC005)
    • Dismantle and Repair powered fire-resisting door, shutter or curtain systems (FRDSC006)
  • Experience
  • Behaviours
  • References/Glossary
Non-Timber and Non-Composite Fire-Resisting Door, Shutter or Curtain Systems

Maintain powered fire-resisting door, shutter or curtain systems (FRDSC004)

You must be able to:

  • demonstrate a range of work skills to maintain a fire-resisting door, shutter or curtain system including:

    • identifying any physical damage or unsanctioned modifications to the system

    • safely cordoning off the work area before commencing any work

    • lubricating and adjusting

    • disassembling and replacing

    • assembling and operating

    • operational checking

    • gap checking

  • risk assess the fire-resisting door, shutter, or curtain system to be maintained to identify the accessibility of all working parts, a safe method of working and individual site-specific hazards

  • ensure the structure into which the system is installed is compatible with the tested scope of the fire rated door and is also suitably structurally sound

  • re-balance and align fire-resisting door, shutter or curtain systems components during maintenance

  • complete planned preventative maintenance of an industrial, commercial, pedestrian, or residential fire-resisting door, shutter or curtain system

  • maintain a fire-resisting door, shutter, or curtain wiring system to the point of isolation

  • maintain control circuits for a fire-resisting door, shutter, or curtain system to specification and safe operating standards

  • adjust, test, verify and troubleshoot a fire-resisting door, shutter, or curtain systems' functionality and its safety components

  • identify when a fire-resisting door, shutter or curtain system is unsafe and needs to be made safe

  • communicate when the safety of a fire-resisting door, shutter or curtain system cannot be established, requires improvement, is critically unsafe and must not be used or has corrective actions that are required

  • communicate operational, safety, training and maintenance information to clients, customers, , end users or their representatives

  • check the functionality of third-party certified fire-resisting door, shutter or curtain systems in line with the manufacturer's instructions

  • record and report the maintenance process to update the golden thread

  • carry out a residual risk assessment and complete any corrective actions required

  • communicate when the equipment you are maintaining is connected to a fire protection or security system that requires additional specialist skills to achieve overall system compliance

Next: Knowledge

You must know and understand:

  • how the following resources should be used and how any problems associated with the resources are reported in relation to:

    • manufacturer's instructions

    • certifications and labels

    • declaration of performance

    • fire stopping materials

    • intumescent seals

    • smoke seals

    • weather seals

    • surrounding construction

    • suitable consumables

    • equipment and instruments for measuring

    • test and inspection equipment

    • hand tools and power tools, and equipment

    • access equipment

    • digital equipment

    • digital methods of product and process traceability

    • activation devices

    • fire-resisting cabling

    • multi-core and single-core cables

    • wiring containment fixtures and fittings

    • electrical motors and starters

    • switch gear and isolators

    • low voltage accessories

    • electrical test equipment

    • uninterrupted power supply UPS battery back-up

  • how to recognise the various resources, parts, components, operating systems, safety devices and intumescent seals that make up a fire-resisting door shutter or curtain system, their suitability for the intended use, functions, interactions, and dependencies on each other

  • the importance of agreeing appropriate ways of working, confirming maintenance requirements and, the impact and implications of incorrect maintenance work

  • how to identify where unsanctioned modifications have been made to the system and report accordingly

  • how to complete a risk assessment

  • the importance of recognising the existing structural composition of mounting and fixing points and identify where the integrity of the structure may not be suitable, report concerns, seek and follow further guidance

  • why it is important to identify and assess the weight and balance of a fire-resisting door shutter or curtain

  • how to correctly use, control and guide lifting techniques and appliances

  • the scope and limitations of maintaining a fire-resisting door, shutter or curtain system

  • that a construction product choice, substitution, modification or recommendation cannot be made and how to ensure no alterations have been carried out which may affect the fire certification of the door, shutter or curtain system

  • how to identify and report where a fire-resisting door, shutter or curtain does not meet specification or is not compliant

  • how to check all component parts and fire stopping materials are compliant with compatible with the certificated system and that no scenario is presented on site that exceeds the limitation of the certification

  • how to inspect and determine the correct maintenance requirements for fire-resisting door, shutter or curtain systems, including adjustments, periodic, scheduled, and event-based planned preventative maintenance

  • when and how to ensure that power supplies and other potential sources of energy are safely isolated and locked off before commencing any work on a fire-resisting door, shutter or curtain system

  • why it is important to refer to parts manuals, guides, technical service bulletins, electronic data and cross reference to troubleshoot and maintain fire-resisting door, shutter or curtain systems

  • how to identify where a planned preventative maintenance procedure is not safe, possible or viable

  • how to position and erect supports

  • when and how to maintain functionality to prevent premature wear and tear of fire-resisting door, shutter or curtain systems

  • when and how to disassemble a fire-resisting door, shutter or curtain system for planned preventative maintenance or replacement of working parts and components, and then reassemble and recommission

  • how to identify the appropriate power supply and maintain wiring, control and containment systems for a fire-resisting door, shutter, curtain system to the isolation point

  • how to integrate control systems with motors, control boards, activation and safety components

  • when and how to maintain activation and safety devices

  • the importance of complying with current electrical regulations

  • single, three phase, low voltage motor operation and earthing requirements

  • how to reverse motor direction

  • the importance of identifying and using the correct methods of electrical testing equipment and methodology

  • how to identify when force testing is required

  • when and how to inspect, check and test safety devices and systems using appropriate testing equipment

  • when and how to check and adjust a fire-resisting door, shutter, or curtain system to ensure safe, compliant and efficient operation within the requirements of legislation, standards and manufacturer’s instructions

  • when and how to test the operation of a fire-resisting door, shutter or curtain system using appropriate testing equipment and why testing is required

  • the correct equipment to inspect and test the safe and efficient operation of a fire-resisting door, shutter, or curtain system

  • how to identify the criteria that constitutes an unsafe system

  • the consequences of failing to communicate the safety status of a fire-resisting door, shutter or curtain issue, and correctly document the issuance of an unsafe system notice

  • how to confirm that the maintenance procedures do not compromise the integrity of the original manufacturer’s fire certification requirements

  • when to communicate the safety status of a fire-resisting door, shutter or curtain system by using “unsafe system”, system safety unknown” notices or applying “do not use” labelling

  • when and how to provide operation, safety, energy saving and maintenance information to client, customer or their representative

  • how to explain automated control and activation systems

  • the importance of ensuring that clients, customers or their representatives are aware that the product being maintained may be offline from the prevention system during the course of the work

  • the importance of recognising any third-party certification and the associated planned preventative maintenance in line with the manufacturer's instructions

  • how to fill out and issue the documentation that is required to update the requirements of the golden thread

  • collaborate effectively within a team environment and be mindful of the needs of other occupations involved in the maintenance process

  • how to carry out a residual risk assessment and complete any corrective actions required

  • how to recognise and communicate when the equipment you are maintaining is connected to a fire protection or security system that requires additional specialist skills to achieve overall system compliance

Next: Dismantle and Repair manual fire-resisting door, shutter or curtain systems (FRDSC005)