You must be able to:
Identify and position specific panels and components in the location and orientation as indicated by drawings
Install all types of fixings used to join wall and floor panels together and to adjoining structure, in accordance with joint drawings and specifications
Install and remove temporary prop in accordance with drawings, specifications and manufacturer's guidance to ensure the panels remain stable during their temporary state
Tension and secure cross-flat bracing members to the correct tension and in the correct sequence in accordance with drawings, specifications and manufacturers' guidance
Fix deflection heads to non-load bearing panels in accordance with drawings, specifications and manufacturers' guidance
Assemble in-fill cold formed steel sticks and ancillary components in accordance with drawings, specifications and manufacturers' guidance
You must know and understand:
How to identify and position specific panels and components in the location and orientation as indicated by drawings
The different types of cold formed steel panel and components, for example load-bearing walls, non-load-bearing walls, floor cassettes, roof elements and how to distinguish between them
How to install all types of fixings used to join wall and floor panels together and to adjoining structure, in accordance with joint drawings and specifications
Fixing types, spacings, torque requirements and quality standards applicable to LSF connections; and the consequences of incorrect fixing on structural performance
The correct sequencing and safety requirements for installing and removing temporary prop, in accordance to drawings, specifications and manufactures' guidance to ensure the panels remain stable during their temporary state
The structural purpose of cross-flat bracing to the correct tension in accordance with drawings, specifications and manufacturers' guidance
The consequences of incorrect tensioning or sequencing on building stability
How to fix deflection heads to non-load bearing panels in accordance with drawings, specifications and manufacturers' guidance
The purpose of deflection heads (accommodating vertical movement between structural floor, roof and non-loadbearing wall panels) and the consequences of incorrect installation
How to assemble in-fill cold formed steel sticks and ancillary components in accordance with drawings, specifications and manufacturers' guidance
The difference between panelised and stick-built (in-fill) LSF construction and when each approach applies
The content and authority of a method statement; and the concept of structural stability during construction and the risks of changing from the agreed sequence